Optical Gas Monitor
Model RK60000
COSA SF6 Purity Pro
Instruction Manual
COSA+XENTAUR CORPORATION LOCATIONS:
84G Horseblock Rd
Yaphank, NY 11980
(631) 345-3434 Fax: (631) 924-7337
7125 North Loop East
Houston, TX 77028
(713) 947-9591 Fax.: (713) 947-7549
email: sales@cosaxentaur.com
www.cosaxentaur.com
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1

1 Optical Gas Monitor Model RK60000 COSA SF6 Purity Pro Instruction Manual COSA+XENTAUR CORPORATION LOCATIONS: 84G Horseblock Rd Ya

Page 2

10 2-5. ERROR Message Display ERROR message and the meanings are as follows: Contents of Display The Meanings and

Page 3

11 2-6. AIR CAL CAUTION If the temperature inside of the sensor has changed over ±10ºC from the last time the AIR CAL was performed, [CAUTION/CHECK

Page 4 - 1. PARTS AND PART FUNCTIONS

12 2-7. Affection on Measurement from Pressure Caution When a concentration change occurs suddenly on the RK60000, the correct reading cannot

Page 5

13 An example of measurement when the pressure of the sampling point is higher than that of the atmospheric pressure: Make an inlet (a) as drawn belo

Page 6

14 3. SETTING MODE (ENTER + POWER) The SETTING MODE is for “Change the Measuring Gas,” “Adjusting the time,” and “Confirming the Saved Data.” Enter

Page 7

15 3-2. Adjusting the Time (SET DATE/TME) The initial position of the cursor is on YEAR. Change this with the keys and fix the setting with

Page 8

16 4. MAINTENANCE 4-1. Replacing the Batteries Warning > All the C-size Alkaline batteries used in the instrument should be the

Page 9

17 4-4. Frequency/Standard for Replacing Parts The frequency of the replacement mentioned below is simply standard. The life of the instrument is d

Page 10

18 6. TROUBLE SHOOTING The trouble shootings mentioned below do not cover all problems, however those that occur most frequently are indicated to he

Page 11 - Caution

19 7. CAUTION OF USAGE The following caution items must be followed to maintain the performance and safety of the instrument. Danger >

Page 12

2 Introduction Thank you for purchasing the Model RK60000. This instrument is a portable gas monitor to measure “Helium in N2,” “CH4 in air,” and ot

Page 13

20 8. Definition of Terms vol%: The rate of substance occupying in some volume. The unit is indicated by percentage. ppm: The rate of substan

Page 14

21 9. SPECIFICATIONS 9-1. Specifications Model Model RK60000 Detection Principle Optical Interferometric Method Display Digital Display (Measuring

Page 15

22 10. MEASURING PRINCIPLE The Reflection ratio of gas mixture is determined by the kinds of composing gases as well as the mixture ratio. As long a

Page 16 - Warning

23 11. WARRANTY COSA INSTRUMENT CO. warrants gas alarm equipment manufactured and sold by us to be free from defects in materials and workmanship fo

Page 17 - 5. DISPOSING THE INSTRUMENT

24 RK60000 EACH TYPE SPECIFICATIONS (TYPE– 51 ~55)

Page 18 - 6. TROUBLE SHOOTING

25 TYPE-51 [FOR SOLVENT GASES (vol%)] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CA

Page 19 - Danger

26 TYPE-52 [FOR SOLVENT GASES (%LEL)] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR C

Page 20 - 8. Definition of Terms

27 TYPE-53 [FOR FUMIGATION GASES] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CAL V

Page 21 - 9. SPECIFICATIONS

28 TYPE-54 [FOR GAS PURITY] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CAL Value D

Page 22 - 10. MEASURING PRINCIPLE

29 TYPE-55 [FOR ANAESTHETIC GASES] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CAL

Page 23 - 11. WARRANTY

3 Index 1. PARTS AND PART FUNCTIONS…………………………………………………………………..4 2. MEASURING MODE (POWER KEY)………………………………………………………………6 2-1. Basic Display for Mea

Page 24 - EACH TYPE SPECIFICATIONS

30 TYPE-56 [FOR CALORIE MEASUREMENT] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CA

Page 25

31 TYPE-58 [FOR SF6 MEASUREMENT] Selectable Measuring Gas and Range Measuring Gas (Display Indication) Measuring Range (Minimum Digit) AIR CAL Va

Page 26

32 Gas Purity Indicator for SF6 (RK60000-SF6) Simple Instructional Manual SECTION 1. POWER ON 1-1. Make sure that the change over cock (measuring ga

Page 27

33 SECTION 2. ZERO ADJUSTMENT 2-1. Adjust the flow rate to be 0.2±0.04 L/min at flow meter “B” (located right on the panel). 2-2. Verify that the

Page 28 - TYPE-54 [FOR GAS PURITY]

34 SECTION 3. PREPARATIONS FOR GAS SAMPLING AND MEASURING 3-1. Connect the sampling tube to the gas inlet “GAS IN” on the panel and apply the sampli

Page 29

35 The higher that the flow rate of meter “A” is set, the sooner its indication will be stable. Also, since the instrument has air in the internal pi

Page 30

36 Operated by AC Adaptor Connect the plug of the AC adaptor to the connector. *1: Exclusive use for the model RK60000, an optional accessory. *

Page 31

4 1. PARTS AND PART FUNCTIONS TOP (1) POWER key: Press this key to turn the power on until the buzzer beeps. Keep pressing the key for approxim

Page 32 - Simple Instructional Manual

5 ***Explanations in the ( ) are for use during SETTING MODE. Tubing Structure (10) GAS IN Inlet for measuring gas. A specific absorption tube m

Page 33

6 2. MEASURING MODE (POWER KEY) 2-1. Basic Display for Measuring Mode and Explanation Display Contents Status Gas Name and Base Gas Standard meas

Page 34 - SECTION 4. START MEASURING

7 2-2. Procedures from Power ON to Measurement 1) The power is turned on by pressing the POWER key until the buzzer beeps. The initial display (self-

Page 35

8 completed, press the PUMP key and let the sample gas draw into the instrument. The color of the display will reverse while the pump is operating

Page 36 - Operated by Dry Cell

9 2-3. Saving Data 2-4. Initial Display (Self-Diagnostic Display) Once the SAVE key is pres