Cosa-xentaur COSA 9610 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Cosa-xentaur COSA 9610. COSA Xentaur COSA 9610 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GENERAL PURPOSE & EXPLOSION PROOF Version: 1.4.1 Software version: 3.10.0.0 Revision dat

Page 2

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 10 of 44 1.4. EXTENDED (DUAL) RANGE OPTION 1.4.1. Operation When the measuring rang

Page 3 - Table of Contents

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 11 of 44 1.5. SPECIFICATIONS COSA 9610™ WOBBE INDEX ANALYZER 1.5.1. Analyzer perfor

Page 4

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 12 of 44 2. INSTALLATION 2.1. GENERAL Upon receipt and unpacking of the COSA 9610™

Page 5 - 1. INTRODUCTION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 13 of 44 2.3.2. COSA 9610™ in general purpose execution (Type 01 & 02) The COSA

Page 6

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 14 of 44 2.4. MECHANICAL CONNECTIONS 2.4.1. General • Location and amount of c

Page 7

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 15 of 44 • If the body is not damaged the pipe has to be cut just after

Page 8 - 1.3. CALIBRATION PROCEDURE

The COSA 9610ª requires one power supply. ∞ Analyzer electronics (ATEX application).The power has to be connected on the interference

Page 9

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 17 of 44 Signal cables The COSA 9610™ has multiple input and output signals, which ca

Page 10 - 1.4.1. Operation

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 18 of 44 3. IN OPERATION 3.1. START-UP SAMPLE CONDITIONING SYSTEM The sample condi

Page 11 - 1.5.3. Installation

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 19 of 44 Relationship of pressure differential (gas/air) versus Wobbe-Index wi

Page 12 - 2. INSTALLATION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 2 of 44 COSA INSTRUMENT CORPORATION New Jersey Sales Office: Texas Sales &

Page 13

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 20 of 44 !Caution The adjusting screw is located in the gas compartment of the rel

Page 14 - 2.4. MECHANICAL CONNECTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 21 of 44 3.2. START-UP OF THE CONTROL UNIT This chapter describes the procedure

Page 15 - 2.4.2. Sample supply

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 22 of 44

Page 16 - Page 16 of 44

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 23 of 44 The lower right section displays the status of each digital input and output

Page 17

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 24 of 44 Global Settings Menu Tree V2.3.0.0 1. Calibration 1. Start Cali

Page 18 - 3. IN OPERATION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 25 of 44 4. Output (Analog & During Cal) 1. Channel A 2. C

Page 19

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 26 of 44 3.3. PROGRAMMING MENUS The paragraph numbers correspond with the key sequen

Page 20 - !Caution

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 27 of 44 3.3.2. Operation Menu

Page 21 - 3.2.3. Main screen

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 28 of 44 3.3.3. Measurement Menu

Page 22 - Page 22 of 44

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 29 of 44 3.3.4. Output Menu

Page 23

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 3 of 44 Table of Contents 1. INTRODUCTION ...

Page 24 - (warm up delay)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 30 of 44 3.3.5. Communications Menu Submenus 1-3 with default communication sett

Page 25 - (Admin Password 9999)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 31 of 44

Page 26 - 3.3. PROGRAMMING MENUS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 32 of 44 3.3.6. System Menu Passwords: USER: 1234 ADMIN: 9999

Page 27 - 3.3.2. Operation Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 33 of 44 Display Menu

Page 28 - 3.3.3. Measurement Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 34 of 44 3.3.7. Reset Alarms Menu

Page 29 - 3.3.4. Output Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 35 of 44 3.4. TEMPERATURE CONTROLLED OVEN 3.4.1. Furnace temperature control unit T

Page 30 - 3.3.5. Communications Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 36 of 44 NOTE: Set oven temp to 81 2ºC & sample system to 50ºC for standard units

Page 31 - Page 31 of 44

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 37 of 44 4. PREVENTIVE MAINTENANCE 4.1. WEEKLY / MONTHLY MAINTENANCE 4.1.1. Compr

Page 32 - 3.3.6. System Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 38 of 44 4.3. ANNUAL MAINTENANCE • Check the calibration gas bottles for pressure.

Page 33

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 39 of 44 4.4. TROUBLESHOOTING Breakdown -> fault report Test Action No air press

Page 34 - 3.3.7. Reset Alarms Menu

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 4 of 44 3.2.2. Programming the measurement parameters...

Page 35 - EMPERATURE CONTROLLED OVEN

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 40 of 44 4.5. REPLACEMENT OF RESIDUAL OXYGEN SENSOR Before going any further make su

Page 36 - 90ºC for mid-temp models

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 41 of 44 5. INSTALLATION DRAWING Standard drawing shown with optional equipment.

Page 37 - 4. PREVENTIVE MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 42 of 44 6. ORDERING OF SPARE PARTS All spare parts may be ordered quoting number a

Page 38 - 4.3. ANNUAL MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL Ð COSA 9610ª Page 43 of 44CAL.S1.E.0200 DIGITAL COMM. RS-485 MODBUS CAL.S1.E.0520 4 ANALOG OUTPUT OP

Page 39 - 4.4. TROUBLESHOOTING

7. CERTIFICATION Page 44 of 44 1. ATEX CERTIFICATE 2. US/CANADIAN CERTIFICATE This product has been examined against the following standards ATEX

Page 40

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 5 of 44 1. INTRODUCTION 1.1. INTRODUCTION 1.1.1. Purpose of the analyzer The conti

Page 41 - 5. INSTALLATION DRAWING

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 6 of 44 1.2.1. Oven with oxygen sensor The gas/air mixture is burnt catalytically in

Page 42 - 6. ORDERING OF SPARE PARTS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 7 of 44 1.2.2. The sample system (SCS) In the sample conditioning system (SCS), gas

Page 43 - Page 43 of 44

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 8 of 44 1.3. CALIBRATION PROCEDURE The analyzer can be calibrated in three different

Page 44 - 7. CERTIFICATION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL – COSA 9610™ Page 9 of 44 The two-point calibration/validation procedure will be executed as followed: